VP Electric Actuator
Brand:Veapon Model: VP-0050, VP-0100, VP-0200, VP-0500, VP-1000 Ambient Temperature: -25 ~+60 Power: DC12V/24V/220V, AC24V/110V/220V/380V
Phone / Whatsapp / WeChat +86 18905154687
- details
- Selection Table
- Configuration
- Control Circuit
- Structure
- Valve Sets
Product characteristics: Strong Functions: including intelligent regulation,proportion,on-off and signal output type; Compact and Light: only approximately 35% of the volume and weight of traditional products; Beautiful Appearance: the shell is made of die casting aluminum alloy,beatiful and smooth,with less electromagnetic interference; Reliable Performance: using imported brand products for key parts like bearings and electric elements; High Standard Protection: IP68 high standard protection grade; Precise and Wearable: the worm gear output shaft is integrated and forged with special copper alloy,strong and wearable; Tiny Return Difference: the integrated structure avoids key gap clearance and have high transmission accuracy; Safety Assurance: 1500V high-voltage insulation test,F class insulation motor and CE certification to ensure safety; Easy Matching: using single-phase power supply and simple external circuit,or optional for 380V and DC power supply; Easy to Use: free of oiling and spot check,water and rusting proof,and available to be installed at any angle. Multi-Speed: for the stroke time,it is optional for 9s,13s,15s,30s,50s,100s,150s.It is set before delivery; Intelligent and Numerical Control: the intelligent control module is integrated inside the electric actuator,unnecessary for external locator,featuring digital setting,digital tuning,high precision,self-disgnosis and multiple functions;
Product Strength: @Reliable perfomance; @Precision & Wear resistance; @Safety guarantee, @Corrosion & rust prevention 
Veapon Electric Actuator Details: Precise Die-casting of Aluminium Alloy: The shell has been treated by aluminum alloy precise die-casting, the hardness is higher than normal. Its durability extends its service life. SS304 Screw: Cylinder body screws are made of German stainless steel. Fine workmanship, guaranteed quality.

The Produciton Feature: 1. Guaranteed Safety: Pass voltage test of 1500V, F grade insulation motor, guaranteed safety. 2. Intelligent CNC: Digital setting, digital adjusting, highly precision, self diagnosis, one machine with multi function. 3. Powerful function: On-off type, intelligent regulation, proportional type, various signal output type. 4. Precision & anti-wearable: worm wheel output shaft integration is made of forging special copper alloy, high strength, good wear resistance. 
Product Series: VEAPON, Cylinder Material: Alloy aluminum, treated by oxidation; Structure: Double piston, gear & rack type; Available Torque: 510NM~2000NM; Stroke: 90 angle stroke; Supply Voltage: 220V, 240V, 380VAC, 24VDC, 12VDC 
Veapon Electric Valve Selection And Configuration Table
actuator model | standard | optional | power supply | soft seal butterfly valve | hard seal butterfly valve | ventilation butterfly valve | ball valve | time/torque | time/torque | ≤1.0MPa | ≤1.6MPa | ≤1.0MPa | ≤1.6MPa | VP-0050 | 30S/50N.m | 10S/15N.m | AC24V, AC110V, AC220V, AC380V, DC12V, DC24V, DC220V | DN25-DN65 | DN40 | DN50-DN80 | DN15-DN32 | 20S/30N.m | VP-0100 | 30S/100N.m | 15S/50N.m | DN80-DN125 | DN40-DN50 | DN100-DN200 | DN40-DN50 | 20S/60N.m | VP-0200 | 30S/200N.m | 9S/80N.m | AC24V, AC110V, AC220V, AC380V, DC24V, DC220V | DN150-DN200 | DN80-DN125 | DN250-DN300 | DN65-DN80 | 15S/100N.m | 60S/200N.m | VP-0400 | 30S/400N.m |  | DN200-DN250 | DN125-DN150 | DN350-DN400 | DN80-DN100 | VP-0500 | 30S/500N.m | 9S/150N.m | DN250-DN300 | DN150-DN200 | DN400-DN500 | DN100-DN125 | 15S/250N.m | 20S/300N.m | 60S/500N.m | VP-0600 | 30S/600N.m |  | DN300 | DN200 | DN500-DN600 | DN125 | VP-1000 | 50S/1000N.m | 15S/300N.m | AC24V, AC110V, AC220V, AC380V | DN300-DN350 | DN250 | DN600-DN800 | DN125-DN150 | 30S/800N.m | VP-2000 | 100S/2000N.m |  | DN400-DN500 | DN300-DN400 | DN800-DN1000 | DN200-DN250 |
Note: The actuator-valve matching data in the table are for reference only,and the actual data are subject to the manufacturer's torque values. Because of various types of valves,even the same specification and model of valves have different torque values due to differences in manufacturer's production process,quality level,structural type and valve body materials.And in the process of actual use,the valve opening and closing torques always vary greatly due to the system's pressure fluctuations,medium types,site environment,operating characteristics and other factors.To ensure the actuator's stable and reliable operation,it is recommended to reserve an adequate safety factor in type selection,namely:safety factor=20%-30%.
A,B,F,G,H control circuit For the on-off type,there are only full opening and full closing limit positions.After receiving appropriate instruction,the actuator drives the valve to the full opening or full closing position. S2 short-time working system is adopted.The continuous working time is not more than 15 minutes.
C,D type control circuit During the process of actuation,the actuator feedbacks the valve position signals to the central control system at the same time.The C type feedbacks the resistance valve position signal,and the D type feedbacks the analog valve position signal. S2 short-time working system is adopted.The continuous working time is not more than 15 minutes.
Intelligent Regulation Actuator
E type control circuit The intelligent module is inside the actuator,and drives the valve to the appropriate opening positions on receiving commands from the central control system based on changes in the controlled variables(flow,pressure,temperature,liquid level)in the pipeline. It adopts the S4 intermittent working system,with the working frequency per hour up to 1200 times.
Due to the valve's work characteristics,the actuator is required to have a full load starting capacity at the valve's opening,closing and any intermediate position,which requires that the actuator's motor should have a high starting torque.At the same time,the motor must have a small moment of inertia as required by flow(opening)regulation.VP series electric actuator motor adopts a special design to meet those requirements. When the actuator's running is blocked,the motor's temperature will rise rapidly.When the motor's temperature rises to 125℃,the PTC overheat protector embedded in the motor winding will cut off the data circuit to protect the motor and the control system.When the motor's temperature drops to 90-150℃,the circuit will be connected again.
High Performance Intelligent Module
Featured by its unique circuit design,fully imported industrial electronic components,intelligent signal acquisition control module centering on the industrial SCM,VP integrates signal acquisition,processing,feedback and control.With an advanced hybrid integrated circuit,it boasts good stability and control precision as high as 1/1000. It is compact and easy for installation and operation.
Each VP series actuator is delivered along with a handle which can be inserted directly into the manual operation port to drive the valve in case of power failure for on-site control or unloaded to be stored separately and fixed with a dustproof rubber plug screw when the handle is not used.
lectrical and mMechanical Limit Functions
Electrical stroke limit function:when the actuator reaches to the fully-open or fully-closed limit position,a built-in electric limit switch will cut off the circuit to protect the actuator. Output shaft mechanical limit function:when the electrical stroke limit function fails,the actuator's output shaft will be locked by the mechanical limit device to protect the valve from being damaged. The figure shows a position relationship between electrical limit and mechanical limit.
Overtorque Protection Function(optional)
When the valve is clogged during operation(intermediate position)due to debris or foreign objects in the pipeline or any other reason,the actuator's output torque will increase rapidly until it reaches the set value(tripping torque)so that the torque switch will break the circuit to protect the value and the actuator from being damaged.
Heating and Dehumidification Funcion(Optional) The electrical chamber of VP series actuator is optional for a PTC electronic heating element to be used in humid places with a large temperature difference between day and night to prevent the electrical elements from being damaged by condensation.The heater is running continuously,so it is always electrified even when the actuator is not running.
|
|
| Common On-Off type (type A) 
By opening or closing of the circuit, the valve can be opended or closed, and a set of active position signals indicating the full opening and closing of the valve can be output.
|
| Passive Contact type (type B) 
By opening or closing of the circuit, the valve can be opended or closed, and a set of passive position signals indicating the full opening and closing of the valve can be output.
| Opening Signal type (type C) 
By opening or closing of the circuit, the valve can be opended or closed, and the resistance signal corresponding to the opening position is output.
|
| With Position Transmitter Type (type D) 
By opening or closing of the circuit,the valve can be opended or closed, and the current signal corresponding to the opening and closing angle of the valve is output at the same time.
| Intelligent Regulation type (type E) 
The opening and closing angle of the valve is cotrolled by the standard signal input from the external computer or industry instrument, and the corresponding standard signal is output by synchronous feedback.
|
| Direct Current on-off type(type F) 
By switching the positive and negtive poles of external DC power supply, the valve can be opened or closed,and a set of passive contact signals indicating that the valve is fully open or closed can be output at the same time.
| 3-Phase On-off Type (type G) 
By opening or closing of the circuit,the valve can be opended or closed, and a set of active position signals indicating the full opening and closing of the valve can be output.
|
| 3-Phase Passive Contact Type (type G) 
By opening or closing of the circuit,the valve can be opended or closed, and a set of passive position signals indicating the full opening and closing of the valve can be output.
|
Structure Diagram for VP Series of Products
 The Structural chart is for VP-0100/30S/AC220V/F05~F07/NN(passive contact type)
Bom of Material:
No. | Quantity | Part name |
| No. | Quantity | Part name | 1 | 1 | indication window hood |
| 37 | 4 | hexagon socket head cap screw | 2 | 4 | hexagon socket head cap screw |
| 38 | 1 | bearing | 3 | 1 | sight glass |
| 39 | 1 | worm | 4 | 1 | O ring |
| 40 | 1 | flat key | 5 | 1 | electric actuator top cover |
| 41 | 1 | bearing | 6 | 4 | anti-loose hexagon socket head cap screw |
| 42 | 1 | locknut | 7 | 1 | O ring |
| 43 | 1 | worm gear | 8 | 1 | Phillips screw (assembly) |
| 44 | 1 | shaft collar | 9 | 1 | dial |
| 45 | 1 | O ring | 10 | 4 | Phillips screw (assembly) |
| 46 | 1 | oil seal | 11 | 4 | limit switch |
| 47 | 6 | anti-loose hexagon socket head cap screw | 12 | 2 | insulation shield |
| 48 | 1 | Phillips screw (assembly) | 13 | 2 | insulation pad |
| 49 | 1 | dustproof plug | 14 | 4 | hexagon socket set screw |
| 50 | 1 | electric actuator-front cover | 15 | 2 | travel stopper |
| 51 | 1 | electric actuator-deceleration box 1 | 16 | 4 | Phillips screw (assembly) |
| 52 | 3 | bearing | 17 | 1 | electric actuator-internal cover |
| 53 | 3 | electirc actuator-reduction gear assembly | 18 | 1 | Phillips screw (assembly) |
| 54 | 3 | bearing | 19 | 1 | capacitor |
| 55 | 1 | electric actuator-deceleration box 2 | 20 | 1 | electric actuator-housing |
| 56 | 5 | Phillips screw (assembly) | 21 | 2 | limit bolt |
| 57 | 1 | Phillips screw (assembly) | 22 | 2 | external hexagon nut |
| 58 | 1 | dial pointer | 23 | 1 | water-proof cable joint |
| 59 | 1 | pointer pole | 24 | 1 | connecting terminal |
| 60 | 1 | rubber plug | 25 | 2 | Phillips screw |
| 61 | 1 | wavy spring gasket | 26 | 1 | Phillips screw |
| 62 | 1 | bearing | 27 | 1 | O ring |
| 63 | 1 | insulating isolation plate | 28 | 4 | anti-loose hexagon socket head cap screw |
| 64 | 1 | motor stator | 29 | 1 | electric actuator-incoming line cover |
| 65 | 1 | motor rotor | 30 | 1 | bearing |
| 66 | 1 | bearing | 31 | 1 | worm gear |
| 67 | 1 | insulating isolation plate | 32 | 1 | bearing |
| 68 | 1 | motor cover | 33 | 1 | oil seal |
| 69 | 1 | oil seal | 34 | 1 | hexagon socket set screw |
| 70 | 1 | oil seal shield | 35 | 1 | connecting bushing (ISO5211) |
| 71 | 2 | Phillips screw (assembly) | 36 | 1 | mounting seat (ISO5211) |
|
|
|
|
Eelectric actuators can use assembly with various type of valves such as ball valve or butterfly valve, various material valve such as cast iron, WCB, stainless steel SUS304, SUS316, SUS316L, UPVC, CPVC, PPH, PVDF vales, various structure valves such as 2ways, 3ways or 4ways, different conditions such as high temperature, high pressure, acid or alkali...... 
electric three-piece welded ball valve | 
electric 3PCS threaded ball valve | 
electric clamp ball valve | 
electric 2pcs flanged ball valve | 
electric 3ways flanged ball valve | 
electric three-way internal threaded ball valve | 
electric fluorine butterfly valve | 
electric double flange butterfly valve | 
electric wafer type butterfly valve | 
electric UPVC flanged wafer type butterfly valve | 
electric UPVC double union ball valve | 
electric 3way UPVC double union ball valve | 
electric wafer type ball valve | 
electric metal seat eccentric butterfly valve |
|
|
|
|